Ausgeblendete Felder
Books Bücher
" ... where again, of course, the finer the sample is ground for the analysis the greater the possible error from this cause. It may be that a part and occasionally all of the moisture... "
The Analysis of Silicate Ad Carbonate Rocks - Seite 55
von William Francis Hillebrand - 1907 - 200 Seiten
Vollansicht - Über dieses Buch

The American Journal of Science, Bände 169-170

1905 - 1124 Seiten
...heat. Several samples for which the moisture had been determined were laid away in corked test tubes for a number of weeks, after which redetermination...this connection that these measured quantities of adsorbed water are of the same order of magnitude as those usually obtained for the water content in...
Vollansicht - Über dieses Buch

Carnegie Institution of Washington Publication, Ausgabe 31

1905 - 214 Seiten
...heat. Several samples for which the moisture had been determined were laid away in corked test-tubes for a number of weeks, after which redetermination...this connection that these measured quantities of adsorbed water are of the same order of magnitude as those usually obtained for the water content in...
Vollansicht - Über dieses Buch

Bulletin, Ausgaben 303-308

1907 - 874 Seiten
...after which redclerminat ion gave exact l\ the former value. It is worth noting in this connection (hat these measured quantities of absorbed water are of the same order of magnitude :i I ln> e usually obtained for the water content in feldspar analyst's, when1 again, of course, the...
Vollansicht - Über dieses Buch

The Isomorphism and Thermal Properties of the Feldspars

Arthur Louis Day, Eugene Thomas Allen, Joseph Paxson Iddings - 1905 - 174 Seiten
...heat. Several samples for which the moisture had been determined were laid away in corked test-tubes for a number of weeks, after which redetermination...this connection that these measured quantities of adsorbed water are of the same order of magnitude as those usually obtained for the water content in...
Vollansicht - Über dieses Buch

The Isomorphism and Thermal Properties of the Feldspars, Band 2

Arthur Louis Day, Eugene Thomas Allen, Joseph Paxson Iddings - 1905 - 168 Seiten
...heat. Several samples for which the moisture had been determined were laid away in corked test-tubes for a number of weeks, after which redetermination...this connection that these measured quantities of adsorbed water are of the same order of magnitude as those usually obtained for the water content in...
Vollansicht - Über dieses Buch

The American Journal of Science, Bände 169-170

1905 - 1018 Seiten
...•were laid away in corked test tubes for a number of weeks, after which redeterminatiou gave exacth" the former value. It is worth noting in this connection that these measured quantities of adsorbed water are of the same order of magnitude as those usually obtained for the water content in...
Vollansicht - Über dieses Buch

The Isomorphism and Thermal Properties of the Feldspars, Band 2

Arthur Louis Day, Eugene Thomas Allen, Joseph Paxson Iddings - 1905 - 166 Seiten
...value. It is worth noting in this connection that these measured quantities of adsorbed water are of the same order of magnitude as those usually obtained for the water content in feldspar analyses,t where again, of course, the finer the sample is ground for the analysis the greater the...
Vollansicht - Über dieses Buch

The Areas of the United States, the States, and the ..., Ausgaben 302-307

Henry Gannett - 1906 - 644 Seiten
...heat. Several samples for which the moisture had been determined were laid away in corked test tubes for a number of weeks, after which redetermination...absorbed water are of the same order of magnitude as those usually obtained for the water content in feldspar analyses, where' again, of course, the...
Vollansicht - Über dieses Buch

Bulletin of the United States Geological Survey

Geological Survey (U.S.) - 1907 - 220 Seiten
...determined were laid away in corked test tubes for a number of weeks, after which redeterminat ion gave exactly the former value. It is worth noting...absorbed water are of the same order of magnitude as those usually obtained for the.water content in feldspar analyses, where again, of course, the finer...
Vollansicht - Über dieses Buch

Bulletin of the United States Geological Survey

Geological Survey (U.S.) - 1910 - 252 Seiten
...heat. Several samples for which the moisture had been determined were laid away in corked test tubes for a number of weeks, after which redetermination...absorbed water are of the same order of magnitude as those usually obtained for the water content in feldspar analyses, where again, of course, the finer...
Vollansicht - Über dieses Buch




  1. Meine Mediathek
  2. Hilfe
  3. Erweiterte Buchsuche
  4. EPUB herunterladen
  5. PDF herunterladen