" Filling-in studs will be nailed, and door and window caps cut into studs. No woodwork shall come within one inch of a chimney; and framing must be arranged to avoid cutting for pipes, chimney, etc. Truss all openings over three feet wide. "
Building Superintendence: A Manual for Young Architects, Students, and ... - Seite 228
von Theodore Minot Clark - 1903 - 306 Seiten
Vollansicht - Über dieses Buch

Building Superintendence: A Manual for Young Architects, Students, and ...

Theodore Minot Clark - 1883 - 352 Seiten
...porch rafters, 2" x 6", 20" on centres. Hips and valleys, 3" x 9". Piazza and porch plate, 6" x 10". Piazza and porch posts, 8" x 8". Sleepers in basement...paint before setting in place. The basement beams to be sized upon the sleepers, which are to rest on the concrete. The beams of first-story floor to...
Vollansicht - Über dieses Buch

Building Superintendence: A Manual for Young Architects, Students, and ...

Theodore Minot Clark - 1891 - 360 Seiten
...porch rafters, 2" x 6", 20" on centres. Hips and valleys, 3" x 9". Piazza and porch plate, 6" x 10". Piazza and porch posts, 8" x 8". Sleepers in basement...nails to be driven into any chimney. The underside of Bill and ends of girders are to be painted two heavy coats of oil paint before setting in place. The...
Vollansicht - Über dieses Buch

Building Construction and Superintendence: Carpenters' work

Frank Eugene Kidder - 1898 - 558 Seiten
...nreproofing, sec Parti. 275- — Framing. — The building is to be full frame, all framed, braced, spiked and pinned in the best and strongest manner, perfectly...framing drawings. No woodwork is to be placed within I inch of the outside of any chimney and no nails are to be driven into any chimney. [See Section 147.]...
Vollansicht - Über dieses Buch

The Country House: A Practical Manual of the Planning and Construction of ...

Charles Edward Hooper - 1905 - 374 Seiten
...crowning edge up. All timber to be of the sizes shown on the framing plans. Framing. The building is to be framed, braced and pinned in the best and strongest...plumb, and in accordance with the framing drawings. All framing must be kept 2" from the outside of the chimneys, and in no case will the timbers be allowed...
Vollansicht - Über dieses Buch

Building Construction and Superintendence, Band 2

Frank Eugene Kidder - 1906 - 568 Seiten
...fireproofing. see Part I. 275- — Framing. — The building is to he full frame, all framed, braced, spiked and pinned in the best and strongest manner, perfectly true and plumb and ia accordance with the framing drawings. No woodwork is to be placed within I inch of the outside of...
Vollansicht - Über dieses Buch

Contracts and Specifications: A Working Manual of Correct Forms Covering the ...

American School of Correspondence at Armour Institute of Technology, Chicago, James C. Plant - 1907 - 134 Seiten
...or loose ends. CARPENTER WORK Framing. The building is to be full-frame, all framed, braced, spiked, and pinned in the best and strongest manner, perfectly true and plumb. Filling-in studs will be nailed, and door and window caps cut into studs. No woodwork shall come within...
Vollansicht - Über dieses Buch

Contracts and Specifications: A Working Manual of Correct Forms Covering the ...

American School of Correspondence at Armour Institute of Technology, Chicago, James C. Plant - 1908 - 136 Seiten
...or loose ends. CARPENTER WORK Framing. The building is to be full-frame, all framed, braced, spiked, and pinned in the best and strongest manner, perfectly true and plumb. Filling-in studs will be nailed, and door and window caps cut into studs. No woodwork shall come within...
Vollansicht - Über dieses Buch

Cyclopedia of Architecture, Carpentry and Building: Building superintendence ...

1909 - 474 Seiten
...or loose ends. CARPENTER WORK Framing. The building is to be full-frame, all framed, braced, spiked, and pinned in the best and strongest manner, perfectly true and plumb. Filling-in studs will be nailed, and door and window caps cut into studs. No woodwork shall come within...
Vollansicht - Über dieses Buch

Cyclopedia of Carpentry and Contracting ...: Contracting specifications ...

1910 - 472 Seiten
...or loose ends. CARPENTER WORK Framing. The building is to be full-frame, all framed, braced, spiked, and pinned in the best and strongest manner, perfectly true and plumb. Filling-in studs will be nailed, and door and window caps cut into studs. No woodwork shall come within...
Vollansicht - Über dieses Buch

Cyclopedia of Architecture: Superintendence. Contracts. Specifications ...

1912 - 478 Seiten
...or loose ends. CARPENTER WORK Framing. The building is to be full-frame, all framed, braced, spiked, and pinned in the best and strongest manner, perfectly true and plumb. Filling-in studs will be nailed, and door and window caps cut into studs. No woodwork shall come within...
Vollansicht - Über dieses Buch




  1. Meine Mediathek
  2. Hilfe
  3. Erweiterte Buchsuche
  4. EPUB herunterladen
  5. PDF herunterladen