| Theodore Minot Clark - 1883 - 352 Seiten
...porch rafters, 2" x 6", 20" on centres. Hips and valleys, 3" x 9". Piazza and porch plate, 6" x 10". Piazza and porch posts, 8" x 8". Sleepers in basement...paint before setting in place. The basement beams to be sized upon the sleepers, which are to rest on the concrete. The beams of first-story floor to... | |
| Theodore Minot Clark - 1891 - 360 Seiten
...porch rafters, 2" x 6", 20" on centres. Hips and valleys, 3" x 9". Piazza and porch plate, 6" x 10". Piazza and porch posts, 8" x 8". Sleepers in basement...nails to be driven into any chimney. The underside of Bill and ends of girders are to be painted two heavy coats of oil paint before setting in place. The... | |
| Frank Eugene Kidder - 1898 - 558 Seiten
...nreproofing, sec Parti. 275- — Framing. — The building is to be full frame, all framed, braced, spiked and pinned in the best and strongest manner, perfectly...framing drawings. No woodwork is to be placed within I inch of the outside of any chimney and no nails are to be driven into any chimney. [See Section 147.]... | |
| Charles Edward Hooper - 1905 - 374 Seiten
...crowning edge up. All timber to be of the sizes shown on the framing plans. Framing. The building is to be framed, braced and pinned in the best and strongest...plumb, and in accordance with the framing drawings. All framing must be kept 2" from the outside of the chimneys, and in no case will the timbers be allowed... | |
| Frank Eugene Kidder - 1906 - 568 Seiten
...fireproofing. see Part I. 275- — Framing. — The building is to he full frame, all framed, braced, spiked and pinned in the best and strongest manner, perfectly true and plumb and ia accordance with the framing drawings. No woodwork is to be placed within I inch of the outside of... | |
| 1909 - 474 Seiten
...or loose ends. CARPENTER WORK Framing. The building is to be full-frame, all framed, braced, spiked, and pinned in the best and strongest manner, perfectly true and plumb. Filling-in studs will be nailed, and door and window caps cut into studs. No woodwork shall come within... | |
| 1910 - 472 Seiten
...or loose ends. CARPENTER WORK Framing. The building is to be full-frame, all framed, braced, spiked, and pinned in the best and strongest manner, perfectly true and plumb. Filling-in studs will be nailed, and door and window caps cut into studs. No woodwork shall come within... | |
| 1912 - 478 Seiten
...or loose ends. CARPENTER WORK Framing. The building is to be full-frame, all framed, braced, spiked, and pinned in the best and strongest manner, perfectly true and plumb. Filling-in studs will be nailed, and door and window caps cut into studs. No woodwork shall come within... | |
| |