A third pat is exposed in any convenient way in an atmosphere of steam, above boiling water, in a loosely closed vessel for five hours. 23. These pats, to satisfactorily pass the requirements, shall remain firm and hard, and show no signs of distortion,... Practical Cement Testing - Page 168by W. Purves Taylor - 1905 - 320 pagesFull view - About this book
| Geological Survey of New South Wales - 1916 - 1292 pages
...A pat is then»kept in air at normal temperature for twenty-eight days, while another pat is placed in an atmosphere of steam above boiling water, in a loosely closed vessel, for five hours. (2) Time of Setting. — This test is made with a Vicat needle apparatus, and is for determining... | |
| Wood - 1900 - 708 pages
...plate about four inches (4") square, from cement paste of normal consistency. This pat is composed in any convenient way in an atmosphere of steam, above boiling water in a loosely closed vessel for five (5) hours, and at the end of that time shall remain firm and hard, and show no signs of cracking,... | |
| American Society of Civil Engineers - Civil engineering - 1903 - 896 pages
...45° Cent. (115° Fahr.) and maintained at this temperature for 24 hours; or (b), a pat is exposed in any convenient way in an atmosphere of steam, above...boiling water, in a loosely closed vessel, for 3 hours. 74. —To pass these tests satisfactorily, the pats should remain firm and hard, and show no signs... | |
| Architecture - 1903 - 340 pages
...American Society. After keeping the pat of cement in moist air for twenty-four hours, it is exposed in any convenient way in an atmosphere of steam above boiling water in a loosely closed vessel for three hours. It will be seen that this requires the use of no apparatus, not even a thermometer, except... | |
| Albert Bleininger - Cement - 1904 - 414 pages
...temperature of 45° C. (115° F.) and maintained at this temperature for 24 hours; or (b), a pat is exposed in any convenient way in an atmosphere of steam, above...boiling water, in a loosely closed vessel, for 3 hours. 74. To pass these tests satisfactorily, the pats should remain firm and hard, and show no signs of... | |
| Ohio. Division of Geological Survey - Geology - 1904 - 416 pages
...temperature of 45° C. (115° F.) and maintained at this temperature for 24 hours; or (b), a pat is exposed in any convenient way in an atmosphere of steam, above...boiling water, in a loosely closed vessel, for 3 hours. 74. To pass these tests satisfactorily, the pats should remain firm and hard, and show no signs of... | |
| Myron Samuel Falk - Cement - 1904 - 202 pages
...at ordinary temperature, and observed at intervals. 73. — Accelerated Test. — A pat is exposed in any convenient way in an atmosphere of steam, above boiling water, in a loosely closed vessel, for three hours. 74. — To pass these tests satisfactorily the pats should remain firm and hard, and show... | |
| Myron Samuel Falk - Cement - 1904 - 198 pages
...and observed at intervals. 73. — Accelerated Test. — A pat is exposed in any convenient way in on atmosphere of steam, above boiling water, in a loosely closed vessel, for three hours. 74. — To pass these tests satisfactorily the pats should remain firm and hard, and show... | |
| Gaetano Lanza - Engineering - 1905 - 978 pages
...as practicable, and observed at intervals for at least twenty-eight days. (c) A third pat is exposed in any convenient way in an atmosphere of steam, above boiling water, in a loosely closed vessel for five hours. 24. These pats, to satisfactorily pass the requirements, shall remain firm and hard and... | |
| |