Apparatus and Method. — The determination of specific gravity is most conveniently made with Le Chatelier's apparatus. This consists of a flask (D), Fig. Bulletin - Page 371by Ohio. Division of Geological Survey - 1904Full view - About this book
| Geological Survey of New South Wales - 1916 - 1292 pages
...causes a lowering of its specific gravity. When testing such a sample it must be first dried at 100° C. The determination of specific gravity is most conveniently...Le Chatelier's apparatus. This consists of a flask of 120 cu. cm (7-32 cubic inches) capacity, the neck of which is about 20 cm. (7-87 inches) long; in... | |
| American Society of Civil Engineers - Civil engineering - 1903 - 896 pages
...10. — When properly made, this test affords a quick check for underburning or adulteration. 11. — Apparatus and Method. — The determination of specific...Chatelier's apparatus. This consists of a flask (D), Fig. 1, of 120 cu. cm. (7.32 cu. ins.) capacity the neck of which is about 20 cm. (7.87 ins.) long;... | |
| Albert Bleininger, Geological Survey of Ohio - Cement - 1904 - 418 pages
...determination. 10. When properly made, this test affords a quick check for underburning or adulteration. JJ. Apparatus and Method.— The determination of specific...about 2 cm. (7.87 in.) long; in the middle of the neck is a bulb (C), above and below which are two marks (F) and (E) ; the volume between these marks is... | |
| Albert Bleininger - Cement - 1904 - 414 pages
...made, this test affords a quick check for underburning or adulteration. JJ. Apparatus and Method.—The determination of specific gravity is most conveniently...about 2 cm. (7.87 in.) long; in the middle of the neck is a bulb (C), above and below which are two marks (F) and (E) ; the volume between these marks is... | |
| Myron Samuel Falk - Cement - 1904 - 198 pages
...10. — When properly made, this test affords a quick check for underburning or adulteration. II. — Apparatus and Method. — The determination of specific...Chatelier's apparatus. This consists of a flask (D), Fig. I, of 120 cu. cm. (7.32 cu. ins.) capacity, the neck of which is about 20 cm. (7.87 ins.) long;... | |
| W. Purves Taylor - Cement - 1905 - 344 pages
...10. — When properly made, this test affords a quick check for underburning or adulteration. n. — APPARATUS AND METHOD. — The determination of specific...Chatelier's apparatus. This consists of a flask (D), Fig. 1 (see Fig. 138), of 120 cu. cm. (7.32 cu. ins.) capacity, the neck of which is about 20 cm. (7.87... | |
| Frederick Winslow Taylor, Sanford Eleazer Thompson - Concrete - 1905 - 638 pages
...determination. ID. When properly made, this test affords a quick check for underburning or adulteration. 11. Apparatus and Method. — The determination of specific...Le Chatelier's apparatus. This consists of a flask (£>), Fig. 9, of 120 cu. cm. (7.32 cu.* in.) capacity, the neck of which is about 20 cm. (7.87 in.)... | |
| Charles Carroll Brown - Cement - 1905 - 440 pages
...Chemical Industry, and given herein on a subsequent page, is recommended. Specific Gravity. — 5. Apparatus and Method — The determination of specific...Le Chatelier's apparatus. This consists of a flask of 120 cu. cm. (7.32 cu. ins.) capacity, the neck of which is about 20 cm. ( 7.87 ins.) long; in the... | |
| Edwin Clarence Eckel - Cement - 1905 - 802 pages
...determination. 10. When properly made, this test affords a quick check for underburning or adulteration. 11. Apparatus and method. — The determination of specific...with Le Chatelier's apparatus. This consists of a flash of 120 cu. cm. (7.32 cu. inches) capacity, the neck of which is about 20 cm. (7.87 inches) long;... | |
| |