Small Sawmills: Their Equipment, Construction, and OperationU.S. Department of Agriculture, 1918 - 68 Seiten |
Im Buch
Ergebnisse 1-5 von 5
Seite 17
... pump and heater instead of injector and spark arrester extra . The usual specifications for a 25 or 30 horsepower engine attached to locomotive boiler , suitable for class B mills , are- Size of cylinder .. Revolutions per minute ...
... pump and heater instead of injector and spark arrester extra . The usual specifications for a 25 or 30 horsepower engine attached to locomotive boiler , suitable for class B mills , are- Size of cylinder .. Revolutions per minute ...
Seite 19
... pumped into a hot boiler ; it will cause sudden con- traction in the plate . In tubular boilers the handholes should often be opened and all dirt and sediment removed . When boilers are fed in front and blown off through the same pipe ...
... pumped into a hot boiler ; it will cause sudden con- traction in the plate . In tubular boilers the handholes should often be opened and all dirt and sediment removed . When boilers are fed in front and blown off through the same pipe ...
Seite 21
... pump is necessary . Usually the pump runs by steam . If the pump runs badly , make sure the water valves and water pipes are all right before examining the steam end . When the pump is not in use in cold weather open all the cocks and ...
... pump is necessary . Usually the pump runs by steam . If the pump runs badly , make sure the water valves and water pipes are all right before examining the steam end . When the pump is not in use in cold weather open all the cocks and ...
Seite 38
... pump with 100 feet of 24 - inch rubber hose , pounds .. Gallons per minute ... Horizontal distance thrown , feet . Vertical distance , feet .... Pressure of nozzle . 60 40 80 100 pounds . pounds . pounds . pounds . 48 73 97 121 155 189 ...
... pump with 100 feet of 24 - inch rubber hose , pounds .. Gallons per minute ... Horizontal distance thrown , feet . Vertical distance , feet .... Pressure of nozzle . 60 40 80 100 pounds . pounds . pounds . pounds . 48 73 97 121 155 189 ...
Seite 58
... pump and resists the entrance of the water ; consequently , to pump hot water always have the supply above the pump so that it will be supplied from a head . STEAM . Under the ordinary atmospheric pressure of 14.7 pounds per square inch ...
... pump and resists the entrance of the water ; consequently , to pump hot water always have the supply above the pump so that it will be supplied from a head . STEAM . Under the ordinary atmospheric pressure of 14.7 pounds per square inch ...
Andere Ausgaben - Alle anzeigen
Häufige Begriffe und Wortgruppen
12 inches 20 inches axes bevel blow-off blow-off valve boiler boxes bunk cant hooks capacity carriage chain chute circular saw class A mill cost crosscut saw cubic cylinder Discount dray drive edge edger engine and boiler equipment f. o. b. Chicago feed feet long feet per day friction front gang grade hammer handled haul head blocks head saw holes horse horsepower husk frame inches wide inserted-tooth keep kerf Lath length load lumber machine Mandrel pulley mill operator pile pinion planer portable mill pounds pressure properly pump rack rack and pinion raker revolutions per minute rip saws road roll round safety valve Sawdust conveyors sawmill sawyers scale set shaft Shingle skids skidway slabs small mill solid-tooth spark arrester speed steam steel straight straight edge suction pipe surface swamp hook teamster tooth track tree truck tubes usually water gauge weight wheel width wood
Beliebte Passagen
Seite 57 - To find the pressure in pounds per square inch of a column of water, multiply the height of the column in feet by .434. Approximately, we say that every foot elevation is equal to % Ib. pressure per square inch ; this allows for ordinary friction. To find the diameter of a pump cylinder...
Seite 19 - Raise the safety valves cautiously and frequently, as they are liable to become fast In their seats and useless for the purpose intended. 10.
Seite 62 - Circular pitch is the distance from the center of one tooth to the center of the next, measured along the pitch line.
Seite 58 - To compute the capacity of pumping engines, multiply the area of water piston, in inches, by the distance it travels, in inches, in a given time. Deduct 3 per cent for slip and rod displacement. The product divided by 231 gives the number of gallons in time named. To find the...
Seite 61 - Constant of an engine is found by multiplying the area of the piston in square inches by the speed of the piston in feet per minute and dividing the product by 33,000.
Seite 57 - To find the velocity in feet per minute necessary to discharge a given volume of water or liquid in a given time, multiply the number of cubic feet of water by 144, and divide the product by the area of the pipe in inches.
Seite 24 - This distance should be such as to allow of a gentle sag to the belt when in motion. A general rule may be stated thus : Where narrow belts are to be run over small pulleys, 15 feet is a good average, the belt having a sag of i£ to 2 inches.
Seite 58 - Steam is steam containing free moisture in the form of spray or mist, and has the same temperature as dry saturated steam of the same pressure. Saturated Steam is steam in its normal state, that is, steam whose temperature is that due to its pressure; by which is meant steam at the same temperature as that of the water from which it was generated and upon which it rests. Superheated Steam is steam at a temperature above that due to its pressure after leaving the liquid from which it is generated.
Seite 63 - ... the saw line after a cut has been made. The carriage frame is mounted on trucks which travel on tracks, the carriage being actuated by a steam feed, a cable, or a rack-and-pinion device, which propels it back and forth past the head-saw.
Seite 24 - ... 2£ to 4 inches. For main belts working on very large pulleys, the distance should be 25 to 30 feet, the belts working well with a sag of 4 to 5 inches.